Distribution Uniformity Calculator

Turn your catch-can test readings into a low-quarter distribution uniformity (DUlq) and Christiansen's uniformity coefficient (CU), see how they rate against sourced benchmarks, and get a run-time multiplier for uneven coverage.

Your catch-can test

Results update as you type. The run time field is optional.

Readings are

One reading per catch can, separated by commas, spaces or new lines. Use a straight-sided can and read the water depth, or measure volume with a graduated cylinder if every can has the same opening size. How to run a catch-can test

For an adjusted run time (optional)

min

Leave this blank to see just the run-time multiplier. Enter it to see roughly how long the cycle would need to run to compensate for uneven coverage.

Your uniformity result

Based only on the readings you enter.

Enter your catch-can readings to see:

  • low-quarter distribution uniformity (DUlq) and Christiansen's uniformity coefficient (CU)
  • how your zone rates against sourced benchmarks
  • a run-time multiplier for uneven coverage (and an adjusted run time, if you add one)

How much distribution uniformity is enough?

Distribution uniformity describes how evenly a sprinkler zone spreads water across the area it covers, rather than how much water it applies on average. A zone can have a perfectly normal precipitation rate and still leave dry patches if some spots receive far less than others. Catch-can testing measures that spread directly: place open containers across a zone, run it, and compare what each one collects.

The most widely used measure for turf and landscape audits is low-quarter distribution uniformity (DUlq), developed by Merriam and Keller (1978). It compares the driest 25% of catch cans against the average of all of them, which puts the emphasis on the part of the lawn most likely to show stress. Christiansen's uniformity coefficient (CU), from Christiansen (1942), takes a different approach: it averages how far every single reading falls from the mean, so it responds less to a few very dry or very wet cans.

Irrigation Association rating scale for low-quarter distribution uniformity on rotor zones (IA, 2005, as reported in Swanson, Fipps and McAfee's landscape auditing paper).
RatingDUlq
Excellent80% or higher
Very good70–79%
Good65–69%
Fair60–64%
Poor50–59%
Very poorbelow 50%

This scale was built from rotor-zone data, so treat it as a reference point rather than a rule for spray or drip zones. It's also a stricter bar than many real systems clear: a University of Florida study of 25 residential irrigation systems found an average DUlq of about 45% across the sample, with spray-head zones scoring lower than rotor zones on average.

The 65% figure means different things in different places. EPA's WaterSense Single-Family New Home Specification requires new, WaterSense labeled homes to test at a DUlq of 65% or greater on the largest spray-irrigated area. WaterSense at Work, which covers commercial and institutional sites, only recommends aiming for at least 65%. Neither applies as a blanket requirement to irrigation systems generally.

How this calculator works

Enter every catch-can reading from one test run. The calculator sorts them, works out three numbers from the same data set, and rates the result against the scale above.

1. Low-quarter distribution uniformity (DUlq)

DUlq

DUlq (%) = (average of the lowest 25% of readings ÷ average of all readings) × 100

The lowest-quarter group size is the reading count divided by four, rounded to the nearest whole can (minimum of one). Source: Merriam and Keller (1978).

2. Christiansen's uniformity coefficient (CU)

CU

CU (%) = 100 × [1 − (sum of |reading − average| ÷ count) ÷ average]

Source: Christiansen (1942).

3. Run-time multiplier

Multiplier

Multiplier = 100 ÷ DUlq (%)

Extension turf programs describe adjusting an irrigation target by dividing the desired depth, or run time, by DU expressed as a decimal, so the driest quarter still receives roughly the target amount. This is a simpler stand-in for the Irrigation Association's scheduling coefficient method, which samples differently for a more precise multiplier; see the scheduling coefficient calculator for that version.

Rounding policy

DUlq and CU are shown to one decimal place. The run-time multiplier is shown to two decimal places, since small differences compound over a full run time. An adjusted run time is rounded to the nearest minute and labeled "about," since it depends on the multiplier being a reasonable stand-in for your zone. If the driest quarter collected no water at all, DUlq is 0% and the calculator skips the multiplier rather than showing a meaningless, infinitely large number: fix the dry can's cause first. CU can go mathematically negative for extremely skewed readings; this calculator floors it at 0% and flags it as a system problem rather than showing a negative percentage.

When this calculator isn't the right tool

Distribution uniformity calculation example

Eight catch cans on a spray-head zone collected (in inches): 0.20, 0.26, 0.28, 0.33, 0.33, 0.42, 0.54 and 0.63. The zone currently runs for 20 minutes.

  1. Sort and average: the eight readings average 0.37 in.
  2. Lowest quarter: 8 ÷ 4 = 2 cans. The two lowest readings, 0.20 and 0.26, average 0.23 in.
  3. DUlq: 0.23 ÷ 0.37 × 100 = 61.5%, which rates "Fair" (60–64%).
  4. CU: the average absolute deviation from the mean is about 0.117 in, so CU = 100 × (1 − 0.117 ÷ 0.37) ≈ 68.6%.
  5. Run-time multiplier: 100 ÷ 61.5 ≈ 1.63×. Applied to a 20-minute cycle, that's about 33 minutes.

The same calculation in metric

Twelve catch cans on a rotor zone collected (in millimeters): 10, 11, 12, 13, 13, 14, 14, 15, 16, 16, 17 and 18.

  1. Average of all 12: 14.1 mm.
  2. Lowest quarter: 12 ÷ 4 = 3 cans. The lowest three, 10, 11 and 12, average 11.0 mm.
  3. DUlq: 11.0 ÷ 14.1 × 100 = 78.1%, which rates "Very good" (70–79%).
  4. CU: the average absolute deviation is about 1.93 mm, so CU = 100 × (1 − 1.93 ÷ 14.1) ≈ 86.3%.
  5. Run-time multiplier: 100 ÷ 78.1 ≈ 1.28×.

Both examples are original, worked by hand to match this page's calculator exactly. Notice that CU came out higher than DUlq in both cases, which is typical: CU spreads the effect of a few dry cans across the whole average instead of concentrating it in the lowest quarter.

Running the test and using the result

Setting up the catch-can test

Space catch cans in a grid across the zone, commonly about 10 to 20 feet apart for rotors and closer for spray heads, so the pattern is well represented rather than concentrated near one head. Run the zone for 8 to 15 minutes or longer, until there's a readable amount in the driest can, then record every can's reading before pouring any of them out. Testing on a calm day matters: wind blows spray unevenly and can make a well-designed zone look worse than it is.

Applying the result

A low DUlq means the driest part of the zone is under-watered relative to the average, which is usually the more useful number to act on, since it's the part of the lawn or planting bed that will show stress first. If the number is disappointing, look at the factors table below before assuming the schedule alone can fix it: a run-time increase compensates for uneven coverage by overwatering the wetter three-quarters of the zone, which wastes water and can encourage disease or runoff on the parts that already get enough.

Where the multiplier is genuinely useful is as a stopgap while you plan repairs, or when a full irrigation audit isn't practical right now. Once head spacing, nozzles and pressure are fixed, retest, since a repaired zone often needs a much smaller adjustment than the multiplier from before the fix.

Common mistakes

  • Testing with mixed sprinkler types in one zone. Rotors and spray heads rarely apply water at matched rates, which distorts both DUlq and CU. Zone by sprinkler type where possible; see the matched precipitation calculator.
  • Using too few cans. A test with only 4 or 5 cans can look excellent or terrible by chance. Treat small samples as a rough check, not a final verdict.
  • Stopping the test too early. Very short runs exaggerate small measurement differences between cans.
  • Testing right after a repair without retesting later. A single fixed head can raise the average without fixing the low quarter if a different head is now the weak point.

Check local rules first. Some water utilities and new-development approvals set their own audit or uniformity requirements. Where those apply, they take priority over the general benchmarks on this page.

What lowers distribution uniformity

Uniformity problems almost always trace back to how water leaves the sprinkler heads, not to the plants or soil underneath.

Common causes of poor distribution uniformity and what to check.
FactorEffectWhat to adjust
Worn or mismatched nozzlesUneven flow between heads in the same zone lowers DUlq more than CU.Replace worn nozzles; match precipitation rates within a zone.
Poor head spacingGaps without head-to-head coverage create dry spots that pull down the low quarter.Check spacing against manufacturer charts; see the sprinkler head spacing calculator.
Pressure too high or too lowDistorts the spray pattern; high pressure can mist water away, low pressure can under-throw.Check pressure against nozzle specifications; add regulation if needed.
Wind during the testBlows spray off target unevenly, especially on spray heads.Retest on a calm day.
Tilted or sunken headsSends water to the wrong spot, missing nearby cans.Straighten or raise heads flush with grade.
SlopeWater can run downhill after landing, which shifts where it ends up relative to where it fell.Note the slope when interpreting results; consider cycle and soak for runoff-prone zones.
Mixed sprinkler types in one zoneDifferent sprinklers rarely apply water at the same rate, distorting the averages.Zone by sprinkler type.

Frequently asked questions

What counts as a good distribution uniformity for sprinklers?

It depends on the sprinkler type and the rating scale you use. For low-quarter distribution uniformity (DUlq) on rotor zones, the Irrigation Association's rating scale treats 80% or higher as excellent, 70-79% as very good, 65-69% as good, 60-64% as fair, 50-59% as poor, and below 50% as very poor. Spray and drip zones aren't covered by this scale and often measure differently even when they're working well.

What's the difference between DU and Christiansen's uniformity coefficient (CU)?

Both describe how evenly a sprinkler zone applies water, but they weight the readings differently. DUlq focuses only on the driest quarter of catch cans, so it is sensitive to a few very dry spots. CU, from Christiansen (1942), averages how far every reading falls from the mean, so a handful of extreme values move it less. CU numbers usually come out higher than DUlq for the same test data.

Does my sprinkler system have to reach 65% distribution uniformity?

Only in one specific case: EPA's WaterSense Single-Family New Home Specification requires new, WaterSense labeled homes to test at a DUlq of 65% or greater on the largest spray-irrigated area. Outside that program, WaterSense at Work only recommends aiming for at least 65% on commercial and institutional sites; it is not a requirement for irrigation systems in general.

How many catch cans do I need for a distribution uniformity test?

There's no single required number, but more cans give a more reliable average. Audit guidance typically spaces catch cans about 10 to 20 feet apart across a rotor zone, which usually works out to a dozen or more per station. This calculator will run with as few as 4 readings, but treat a test with only a handful of cans as a rough check rather than a formal audit.

What does a low DU mean for my watering schedule?

It means the driest part of the zone needs more water than the average reading suggests, or the rest of the zone is overwatered to compensate. One rough way to adjust is to divide your target watering depth, or run time, by the DU expressed as a decimal, which is what this calculator's run-time multiplier does. It is a simplified stand-in for the scheduling coefficient method, which uses a different sampling approach for a more precise adjustment.

Can I enter volume readings instead of depth?

Yes, as long as every catch can has the same opening area. DUlq and CU are both ratios, so milliliters collected in identical cans give the same result as a depth measurement would. If your cans have different sizes, convert each reading to a depth first.

Why is my distribution uniformity different from my sprinkler's precipitation rate?

Precipitation rate tells you how fast a zone applies water on average. Distribution uniformity tells you how evenly that water lands across the area. A zone can have a normal precipitation rate and still have poor uniformity if some catch cans collect far less than others.

Find your zone's precipitation rate from the same catch-can data with the catch-can test calculator.

Can I use this calculator for drip irrigation?

Not directly. Drip systems are usually evaluated with emission uniformity, which compares emitter flow rates rather than catch-can depths.

See the emission uniformity calculator for drip and micro-irrigation zones.

Who built and checked this calculator

Daniel Reeves

Irrigation Design Engineer & Water-Efficiency Specialist

Licensed Professional Engineer and Irrigation Association Certified Irrigation Designer with more than 20 years in irrigation design, system auditing and landscape water management. Full profile

How this page was checked

  • Formulas, the low-quarter grouping and both worked examples verified by hand against the calculator's code.
  • DUlq, CU and the WaterSense thresholds checked against the sources below.
  • Methods follow Irrigation Association and landscape irrigation auditing practice.

Last reviewed . Methodology, editorial policy, report an error.

Sources